Large blower on Amana 80 SSE wont go on. Small fan goes on and burner is lit.
It will be one of three issues. Blower motor is bad , capicator, or the control board. Easy enough to check . Use an extension cord , cut off the female end and strip it . You should have a black and white wire. Find the wires leading to the motor take the black and white off the control board conect black to black and white to white. Plug it in an outlet if the motor runs its the control board . If not its a bad motor or capicator. But caps rarely go bad in this use . So most likely motor . Not a hard job , but not eady if you dont have the right tools. Do not bang on the shaft with a hammer . You must use a special tool for pulling shafts.
Air intake via hose & window or intake from room only?
Hello artrey3 The answer is yes, BUT the unit will be exausting room/basement air outside ruining any efficency the unit is rated for.Also you will need makeup/fresh air in the basement. The unit exausting air can put the basement in a vacuum/negitive pressure pulling in air from the chimney!