Wiring an electric dryer
If you are referring to the breaker / fuse box to the dryer recepticle, you would use 10-3 NM w/ ground. (that is 4 conductor wire: 2 "hot", one neutral, and one ground.) If you are referring to the dryer to the recepticle, use a pre-made dryer cord, either a 3 wire or 4 wire, depending on which recepticle your home has.
INGLIS DRYER MODEL IP82000 RUNNING BUT NO HEAT.
Check the following to address this issue.
1. No power to the dryer
Make sure there's power getting to the dryer. Check for tripped circuit breakers or blown fuses. An electric dryer uses two circuit breakers or fuses, and if only one of two is tripped or blown, the dryer might still run but not heat. Sometimes the power cord disconnects or burns at the dryer, if this is the case, the wiring and the terminal block must be repaired or replaced.
2. Heating element
A burned out heating element will show no continuity when measured with a meter. Replace the element if found defective.
3. Thermal fuse
Most dryers have a thermal fuse, which burns out when the dryer overheats, in which case the dryer will either not run at all or stop heating. The fuse is usually located on the vent duct, inside the dryer. A blown fuse will show no continuity when measured with a meter. Before replacing the fuse, make sure the blower wheel is not broken or clogged, and there is nothing blocking the venting.(((((Most common issue)))))
Do you have a digram to show you how to change belt on inglis dry
Diagram A Style: Flat with ribs
Installation Tips: Ribs face toward drum
Diagram B
Style: Flat with ribs
Installation Tips: Ribs face toward drum
Diagram C
Style: Flat with ribs
Installation Tips: Ribs face toward drum
Diagram D
Style: Flat with ribs
Installation Tips: Ribs against drum
Diagram E
Style: Flat with ribs
Installation Tips: Flat side of belt against drum
Diagram F
Style: Flat with ribs
Installation Tips: Ribs against drum
Diagram G
Style: Flat belt
Installation Tips: Side of belt with words faces away from drum
Diagram H
Style: Flat with ribs
Installation Tips: Ribs against drum
Diagram J
Style: Flat with ribs
Installation Tips: Ribs against drum
Diagram K
Style: Flat with ribs
Installation Tips: Ribs against drum
Diagram L
Style: Flat with ribs
Installation Tips: Ribs against drum
Diagram M
Style: Flat with ribs
Installation Tips: Ribs against
Dryer will tumble but there is no heat for drying
The fault can be a faulty dial switch, faulty wiring or the element may need replacing.
Use a multimeter on ohms to check the element.
Use a multimeter on AC Volts to check if there is voltage on the element when switched on - be careful and dont do this if not technically minded.
If no voltage - check the switch with a multimeter on ohms.
Whirlpool WGD4800XQ1 Dryer-- Replaced burner coils and it worked great. The next day no ignition again.
There are about seven different possiblities and the prospective solution in each case appears to be replacement of a different part! I suppose if you have the proper testing equipment for assessing each of those parts, you might be favored with a relatively inexpensive fix. I would be embarassed to suggest you replace all in sequence until the dryer works.
Thermal Fuse: The thermal fuse is a safety mechanism that prevents the dryer from overheating. If it blows, the dryer won't heat. Check if the thermal fuse is intact and replace it if necessary.
Cycling Thermostat: The cycling thermostat regulates the temperature inside the dryer drum. If it's faulty, the dryer may not heat properly. Consider checking and replacing the cycling thermostat.
Igniter: The igniter is responsible for lighting the gas burner. If it's defective, the dryer won't ignite. Inspect the igniter for any signs of damage or malfunction.
Gas Valve Coils: Although you've already replaced them, double-check the gas valve coils. Sometimes, even new parts can fail. Ensure they are securely connected and functioning correctly.
Ventilation: Poor ventilation can lead to longer drying times and affect ignition. Make sure the dryer vent is clean and not obstructed. A clogged vent can cause overheating and affect ignition.
Door Switch: The door switch ensures the dryer doesn't operate when the door is open. If it's faulty, the dryer won't start or heat. Verify that the door switch is functioning properly.
Timer and Controls: Check if the timer advances correctly during the drying cycle. Malfunctioning controls can impact ignition. Inspect the timer and control board for any issues.
Whirlpool Dryer WGD4800XQ1 - OEM Parts & Repair Help - PartSelect.com
On a cabrio whirlpool dryer what does E4 and F4 codes mean
A "F4E4" (Low or No Line Voltage) code indicates there may be a problem with your home power supply, keeping the dryer's heater from turning on. The dryer will continue to run when this diagnostic code is present. Touch any pad to clear the code from the display and return to the estimated time remaining.
Whirlpool duet model YWED9300VU0
Try kit 4392067. It's the 4 roller wheel kit with belt and pulley. I use them all the time on that model, but without the Y in the beginning. Not sure what the variation is there.