Compool LX3800 isn't starting pool filter, booster pump, or spa bubbles after power outage

If you are unable to get the booster pump, filter pump, or spa bubbles to turn on, even though everything seems to be fine and you are getting 120V at each item, it could be due to a number of issues. Here are some steps you can take to troubleshoot the problem:
  1. Check the circuit breaker: Make sure that the circuit breaker for the equipment is not tripped or turned off. Reset the circuit breaker if necessary.
  2. Check the power source: Verify that the power source is functioning properly by using a voltmeter to check the voltage at the outlet.
  3. Check the relays: If you hear the click of the relay, it could be a sign that the relay is working but not properly connected. Check the wiring and make sure that the relay is properly connected.
  4. Check the pump and motor: If the pump and motor are not working, it could be due to a problem with the motor, impeller, or other parts. Check for signs of damage, wear, or obstruction.
  5. Check the pressure switch: If the pressure switch is not working, it could prevent the booster pump from turning on. Test the pressure switch with a multimeter and replace it if necessary.
  6. Check the timer: If you have a timer, check that it is set properly and not malfunctioning.
  7. Check the control panel: If you have a control panel, check that it is working properly and not malfunctioning.
If you have tried these troubleshooting steps and still cannot get the equipment to turn on, it may be time to call a professional technician to diagnose and fix the issue.
3/25/2023 5:25:45 AM • Pool & Spa • Answered on Mar 25, 2023
0helpful
2answers

Cen tech 60581 battery charger wiring and parts lay out.

@Steve Halver No a good idea adding your question to the section where you ask the OP for further information, AND the question is from February 2015!! We don't send anything to anybody. We are all ordinary people like you who help others because we can. Everything is done on the website. https://www.google.com/search?q=cen-tech+69368+battery+charger+wiring+diagram
3/23/2023 5:13:23 PM • Pool & Spa • Answered on Mar 23, 2023
0helpful
3answers

1999 Sundance Sentry 850 Spa.

No service manual unfortunately

Sundance 2004 850 Owner's Manual (60 Hz) - The Spa Works

The Spa Works https://www.thespaworks.com > sites > default > files PDF The Sentry control system allows you to easily adjust two separate aspects of circulation pump operation: 1. The time of day (start time) the circulation pump ...
3/14/2023 1:12:18 AM • Pool & Spa • Answered on Mar 14, 2023
0helpful
1answer

Pool timer goes into sleep mode but continued to run

No make or model, but there is generic help and help specific to Intermatic. https://www.google.com/search?q=Pool+timer+goes+into+sleep+mode+but+continued+to+run ..
3/10/2023 12:08:37 AM • Pool & Spa • Answered on Mar 10, 2023
0helpful
1answer

After my pool timer go into sleep mode it didn't shut off

If your above ground pool timer is not automatically shutting off while in sleep mode, there could be a few reasons why this is happening:
  1. Timer is not set up properly: Make sure that the timer is set up correctly and all the settings are configured as per the manufacturer's instructions. Check the user manual to ensure that you have set the timer correctly.
  2. Faulty timer: Your timer may be faulty or damaged. Try resetting the timer and if the issue persists, it may be necessary to replace it.
  3. Power surges: Power surges can cause electronic devices like pool timers to malfunction. Check to make sure there were no power surges or outages that may have affected the timer's function.
  4. Wiring issues: Check the wiring connections to ensure that they are secure and properly connected. Loose or damaged wiring can cause the timer to malfunction.
  5. Software update: If your timer is connected to a Wi-Fi network or has an app, make sure that the software is up to date. Software updates can often fix bugs and improve performance.
If you have tried these troubleshooting steps and the timer still does not automatically shut off while in sleep mode, it may be best to contact a professional electrician or the manufacturer's customer support for further assistance.
3/8/2023 2:47:13 AM • Pool & Spa • Answered on Mar 08, 2023
0helpful
1answer

Need circuit diagram for Maytronics power supply 9995678

I don't think there is one. The manufacturer, if still within service date, will service it for you.
2/26/2023 11:21:50 AM • Pool & Spa • Answered on Feb 26, 2023
0helpful
2answers

LAARS LT pool heater control has no power. Control lights do not light up - Is the control gone bad or is there another problem. Unit is approximately 15 years old but we never used!

check voltage to unit if ok keep checking till voltage drops possible bad transformer or display board
2/18/2023 9:01:29 AM • Pool & Spa • Answered on Feb 18, 2023
0helpful
1answer

What is the part number for the control knob for the Bernzomatic Patio Heater model # PH3250N?

Bernzomatic does not provide nor sell replacement parts for their products - they consider them disposable. If the plastic knob is the only piece you need, Amazon sells a few replacement knobs for patio heaters. I searched Amazon with the terms: replacement knob patio heater
2/16/2023 11:06:35 AM • Pool & Spa • Answered on Feb 16, 2023
0helpful
1answer

Is it possible for a centrifugal pump briefly rotated counterclockwise to unscrew itself and make the impeller detached from the shaft.. can the motor put to blame ..thanks

Yes, it is possible for a centrifugal pump to unscrew itself if it is briefly rotated counterclockwise, which can cause the impeller to become detached from the shaft. However, the motor is not necessarily to blame in this scenario. There could be various reasons for this occurrence such as improper installation, vibration, or a problem with the pump itself, such as an impeller that is not securely attached to the shaft. In order to prevent this from happening, it is important to follow proper installation and maintenance procedures, as well as to regularly inspect the pump for any signs of wear or damage. If the pump continues to unscrew itself, it may be necessary to have it repaired or replaced.
2/13/2023 7:55:33 AM • Pool & Spa • Answered on Feb 13, 2023
0helpful
1answer

Why does impeller disconnect from shaft in a counter clockwise rotation.

the pump is designed to rotate and tighten impeller, reverse rotation will cause it to unscrew. replace with correct rotation motor.
2/13/2023 3:48:18 AM • Pool & Spa • Answered on Feb 13, 2023
0helpful
1answer

Can a centrifugal pump run in the opposite direction, will it damage the pump..

is it physically possible to have pump run in opposite rotation, yes it is but it will not pump and depending on pump the impeller will unscrew and push against volute and damage pump or burn motor up.
2/13/2023 3:46:39 AM • Pool & Spa • Answered on Feb 13, 2023
0helpful
1answer

Astral Pool Hurlcon VX6T won't turn off unless I turn the power off?

possible bad switch or relay
2/4/2023 8:03:23 AM • Pool & Spa • Answered on Feb 04, 2023
0helpful
1answer

Where on remote is the vout button on flo remote

vout button? flo remote? Aall questions need 'make model (what it is)', and a cohernt question. Proof read, make sure it is in the correct category (there are over 10,000) and press Post. Too vague and makes no sense as written and posted to Pool and Spa category. Google thinks it is something to do with a television? https://www.google.com/search?q=vout+button+on+flo+remote ..
2/3/2023 11:59:13 PM • Pool & Spa • Answered on Feb 03, 2023
0helpful
2answers

Intex Spa suddenly says the water is 109 degrees, when it is actually less than 70. I cannot get the water to heat because the spa thinks it is at 109 degrees.

I have same issue, reading 103/104 but barely 80 degrees. Im guessing tstat went bad how can the gfi plug cause this? are you referring to the actual gfi plug for outlet?
12/29/2022 6:08:47 AM • Pool & Spa • Answered on Dec 29, 2022
0helpful
2answers

My Dreammaker Cabana 2500 suite spa keeps a EE error code - please help me get rid of it.

Eontact them direct. This is an unknown, undocumented fault but am guessing EE is Electrical Error.

Suite Collection - Owner's Manual PU2 - Dream Maker Spas

https://dreammakerspas.com > uploads > 2019/02 PDF Always keep an accurate thermometer in the water because your spa's thermostat may be in error. Use a high quality, shatterproof. Missing: EE ‎' Must include: EE
12/29/2022 6:02:12 AM • Pool & Spa • Answered on Dec 29, 2022
0helpful
2answers

How do l remove motor from Ultra pro lx series pump housingit comes out about 2incges then gets stuck on the housing

You need to remove the impeller 1st.....there is usually(not familiar with your particular pump) 2 sets of exterior accessible bolts. One set separates the front and rear of the pump(where the impeller is), and where the motor meets the pump(where it sounds like you have). https://www.youtube.com/watch?v=mpJLp3oWDGU I hope this helps.
12/29/2022 5:55:51 AM • Pool & Spa • Answered on Dec 29, 2022
0helpful
2answers

Leisurerite spa now shuts down intermittently with circuit breaker tripping out. Any ideas?

limited info generic answer need a multi-meter to test circuits usually heater failure or pump failure but the relays and circuits can get critters or condensation damage
12/29/2022 5:47:48 AM • Pool & Spa • Answered on Dec 29, 2022
0helpful
1answer

Aquacal sq110 is not heating water - no errors on display

possible heat element bad or temp sensor
12/16/2022 5:05:48 AM • Pool & Spa • Answered on Dec 16, 2022
0helpful
1answer

Why does my sauna tech heater keeps shutting off as soon as it heats up

possible bad temp sensor
12/16/2022 5:00:50 AM • Pool & Spa • Answered on Dec 16, 2022
Not finding what you are looking for?
NRS CANTAR GLOW BUOY FLOATING POOL LIGHT 92000 Logo

50 questions posted

Ask a Question

Usually answered in minutes!

Top NRS Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

David Spradling
David Spradling

Level 3 Expert

13520 Answers

Are you a NRS Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

NRS Pool & Spa

  • NRS Pool & Spa

Most Popular Question

glowbuoy light battery needs replacement

  • Pool & Spa
Loading...