When I turn on my SHU9915UC dishwater the drain
It is best atleast to get a better idea of the problem by running the diagnostic on the dishwasher. I cannot find a manual for it on the internet but there is a diagnostic routine that might be helpful.
SHU 991x/992x (Integra) MODELS
To start test program, press and hold both POWER SCRUB PLUS and REGULAR WASH program buttons, then turn unit on by pressing ON/OFF button. When program buttons are released, lights above them will flash. To end test program, press ON/OFF button.
To check program indicator lights (POWER SCRUB PLUS, SCRUB WASH, REGULAR WASH and RINSE & HOLD), press and hold each program button. When SCRUB WASH program button is pressed, CLEAN light also comes on andan audible tone (�beep�) also occurs.
To start testing, press both POWER SCRUB PLUS and REGULAR WASH buttons a second time.
When testing has ended and a fault was detected, the following indicator lights will be lit:
POWER SCRUB PLUS = Heater fault
SCRUB WASH = Water filling fault (over or under filling)
REGULAR WASH = NTC (temperature sensor) fault � note circulation motor stops shortly after it started during an NTC fault
To check for heater, high limit or flow switch problems, start testing until heating starts. Using a meter with a current coil, measure current going into dishwasher. If current is ~ 11 A, then heater, high limit and flow switch are OK. If current stays at ~ 1.5-2 A, then heater, high limit or flow switch are faulty.
If water level switch (f1) has failed (opened), SCRUB WASH light will come on and unit will continually fill and drain where testing won't be completed. If flow switch (e5) has failed (opened), water won't heat (to 150�F) and water won�t stop circulating. If NTC probe (f2/f4) has failed (opened), REGULAR WASH light will come on immediately and testing will end shortly after water has started circulating.
If more than one fault occurs, more than one light will be lit.
This will atleast confirm if the water fill valve or the water float is the problem. (maybe it is thinking it is already full).
Please do drop a comment to tell if this diagnostic works.