20 Most Recent
Precor 9.21 Treadmill - Page 6 Questions & Answers
What causes a slow boot up on a Precor EFX 546?
A slow boot up on a Precor EFX 546 elliptical machine can be caused by several factors, including:
- Low battery voltage: If the battery voltage is low, the machine may take longer to boot up. This can be due to a weak or old battery, or a problem with the battery charger.
- Dirty or corroded contacts: Dirt, dust, or corrosion on the battery contacts or other electrical contacts can interfere with the machine's ability to start up quickly.
- Faulty console or display board: If the console or display board is malfunctioning, it may take longer for the machine to boot up or may not boot up at all.
- Loose or damaged cables or connections: Loose or damaged cables or connections can prevent the machine from starting up properly and may cause a slow boot up.
- Outdated software: If the software on the machine is outdated, it may take longer for the machine to boot up or it may not start up at all.
To troubleshoot a slow boot up on a Precor EFX 546, you can try the following steps:
- Check the battery voltage and replace the battery if necessary.
- Clean the contacts on the battery and other electrical components.
- Inspect the cables and connections for damage or looseness.
- Check for any error codes or messages on the console or display board and consult the user manual for troubleshooting steps.
- Check for any available software updates and install them if necessary.
If none of these steps resolve the issue, you may need to contact a professional technician for further assistance.
Precor 556i / AXGE....Problema with the resistance. Can anybody help me?
Hey Fabian, it's possible that the resistance motor or sensors on your wife's Precor 556i/AXGE may need to be recalibrated. Try powering off the machine, unplugging it for a minute, and then plugging it back in to see if that resets the calibration. If the problem persists, you can try recalibrating the machine manually. There should be instructions in the user manual or online. If that doesn't work, then contacting customer service or a certified technician may be necessary. I hope this helps!
Precor 9.45 reset safety switch message wont go away
If you have checked the safety switch on your Precor 9.45 treadmill and everything seems to be intact, and the "reset safety switch" message still won't go away, it's possible that the switch itself is faulty or the console is not receiving the signal from the switch.
You can try cleaning the switch and the area around it, and also check the wires that connect the switch to the console to make sure they are not damaged. If the switch or wires appear to be damaged, they may need to be replaced.
If cleaning and checking the switch and wires doesn't resolve the issue, it's recommended that you contact the manufacturer or a qualified repair technician to further diagnose and fix the problem. They may be able to provide additional troubleshooting steps or suggest other possible solutions.
Precor treadmill making squeaking noise when running fast
Two likely candidates: Belt or tread. Lubricating the tread would be the easiest starting point; but if you're running at 7 or more you've probably already thought of that.
If the cover isn't too difficult to remove, you can expose the drive belt and the squeaking volume change would be an indicator that the drive belt is the problem.
Precor 546i
https://www.precor.com/en/efx®-546i-elliptical-fitness-crosstrainer™
use of:
https://www.youtube.com/watch?v=YRFJNFIHAHY