Honda 30is generator
dear sir i have one honda 30is it not working when i on the key that showing E-03 what is the problem let me now
I have a Honda EU 2000i generator. With eco switch
starving for fuel. the generator will always rev up when it is under a load or about to run out of gas. there will be a few adjustment screws on the carb... one for air and one for fuel. try increasing the fuel a quarter turn and see how that does
Smoke on startup
check air fuel mixture screw on the carb possibly air fuel ratio is not proper adjust it or check if your spark plug is oil wet after a brief run (otherwise should be brownish ) that means oil is leaking in the piston head due to worn out piston rings have to replace them
Honda e2000i generator no spark
if there is no spark in the plug as you are saying for that matter check the current coil and the inverter section for the loss of current if you have already changed the sparkplug if not do change