My Honda EV6010 generator will

Check the oil level, low oil will stop the engine from continued running
11/6/2018 9:43:32 PM • Honda Electrical... • Answered on Nov 06, 2018 • 1,869 views
0helpful
1answer

I have a 8000w Honda generator it has a circuit board con I wire around it

Yes, if you have the circuit diagram because it produce different voltage output some terminals if you got wrong your wire going to burned.
10/16/2018 6:30:32 AM • Honda Electrical... • Answered on Oct 16, 2018 • 95 views
0helpful
1answer

Ex1000 honda generator getting no gas to sparkplug. new plug,, dry when taken out after trying to start. generator has sat for 1+ year

Carburetor, injectors likely gummed up. It is a common problem. Try spraying carburetor cleaner into the intake and get it to run briefly by burning the cleaner. Keep trying that until you get it to run.
10/2/2018 6:16:26 PM • Honda Electrical... • Answered on Oct 02, 2018 • 699 views
0helpful
1answer

I have a EB10000 Honda generator there are problems with it starting clean gas has been put in tank and is running up to carb I have taken the fuel lines off and the fuel is definetley coming through

There are several problems it could be other than fuel. Have you checked you have got a spark. Have you checked that the choke is working. Have you checked that the ignition circuit is live when you turn the key to on. Have you checked the air cleaner is not blocked. Have you checked that the exhaust is not blocked. When was the last time you had it serviced.
9/1/2018 11:08:43 AM • Honda Electrical... • Answered on Sep 01, 2018 • 884 views
0helpful
1answer

I have a 4200 generator with a 9hp honda it starts and runs when i try to run a saw it shuts down and backfires

How to test your Electricity Generator AVR Brushes and Alternator on... You need to run these tests in the video and come back to us with the results. Send your test results to us here: https://www.generatorguru.com/ask-the-guru/ Then we can tell you what the problem is :)
8/3/2018 1:43:11 PM • Honda Electrical... • Answered on Aug 03, 2018 • 258 views
0helpful
1answer

With honda e2500 generator can I re use alternator on a different set where alternator will run in opposite direction

yes alternators are not rotation sensitive
7/13/2018 5:33:04 PM • Honda Electrical... • Answered on Jul 13, 2018 • 210 views
0helpful
1answer

2011 honda eb5000x generator will not crank

check for low oil level controller
5/12/2018 2:22:53 AM • Honda Electrical... • Answered on May 12, 2018 • 134 views
0helpful
2answers

My 2011 honda eb5000x generator will not crank

Is the battery fully charged or has it been load tested?
5/12/2018 1:05:30 AM • Honda Electrical... • Answered on May 12, 2018 • 203 views
0helpful
1answer

My EU 2000 honda generator seems louder than normal Whats the problem

SSounds like either you have a hole in the muffler or the muffler bolts loosened up.
3/19/2018 1:27:59 AM • Honda Electrical... • Answered on Mar 19, 2018 • 433 views
0helpful
1answer

Backfires power

Sticky inlet valves
2/7/2018 6:52:39 PM • Honda Electrical... • Answered on Feb 07, 2018 • 83 views
0helpful
1answer

How to measure the stator on a honda ex 5500 generator

You need a volt meter an ammeter and a variable power supply and with ohms law the resistance can be calculated. V=IR thus resistance is the applied voltage devided by the current R=V/I Set the psu till a convenient current is indicated on the ammeter and take an accurate voltage reading and do your calculation. Normal multimeters cannot read reliably below one ohm and these rotors do have a low resistance
2/7/2018 6:51:57 PM • Honda Electrical... • Answered on Feb 07, 2018 • 371 views
0helpful
1answer

EMS 4000. Why is it difficult to pull and won't start?

THAT POOR ENGINE HAD TO RUN WITHOUT LUBRICANT AND IS SEIZED UP
2/7/2018 6:35:36 PM • Honda Electrical... • Answered on Feb 07, 2018 • 146 views
0helpful
1answer

Electric starter will not work on honda e u 3000 generator

Hi there! 1) Check battery with a load tester and recharge / replace if necessary 2) Check the ignition switch for loose wires or if the switch is okay 3) Remove the starter and try to run it against a piece of wood ( Have you seen the wooden hammer handle of an auto electrician?) If you can stop it then the motor needs repair/replacement it is often cheaper to replace than repair it excluding labour!! 4) Check ringear on the flywheel and the pinnion of the starter motor for binding and wear. Keep these tips in mind for your Automobiles too
2/7/2018 6:33:38 PM • Honda Electrical... • Answered on Feb 07, 2018 • 884 views
0helpful
3answers

I have a honda ex 5500 generator that keeps triping the on and off breaker to the outlets what could it be

Hi there. 1) Remove all loads and start up.2) Connect a known working load and if it trips on a load too small then the tripswitch is faulty and must be replaced
2/7/2018 6:14:28 PM • Honda Electrical... • Answered on Feb 07, 2018 • 376 views
0helpful
1answer

My 5.5kva Honda generator has no voltage and voltage meter also not showing voltage. What can be wrong?

Hi there I had a similar problem years ago. 1) check brushes on the sliprings of the alternator 2) There is a small pcb on the brush gear and an electrolytic capacitor some diodes etc. check for bad joints or capacitor 3) lift off one brush from sliprings and connect for a couple of seconds a 12 volt battery to it. Why? The rotor must have some residual magnetism for it to develop excitation and sometimes if the genny was not used at all for a long time then that magnetism sometimes die away. It also happen if the genny was disassembled for one reason or another Good luck
2/7/2018 6:02:37 PM • Honda Electrical... • Answered on Feb 07, 2018 • 213 views
0helpful
1answer

Hi I have a Dunlite UH5 generator coupled to a Honda GX 340 Generator is noisy. Is there a parts list or workshop manual I can get to explain how to identify and repair the generator ?

Hi, You can get parts from "Generator Guru" for your Dunlite generator and your Honda, as it sounds like the anti vibration engine mounts are shot. Sorry, but I can't help you with the manuals. Kind regards David
1/16/2018 8:46:10 PM • Honda Electrical... • Answered on Jan 16, 2018 • 493 views
0helpful
2answers

How to make my black max 8125 generator quieter!?

My friend has one, and after he starts it, he places a small mini shipping crate over it (like the kind you see in photos of cargo ships). Seems like the crate is made of some kind of plastic or fiberglass, and he has a short flexible steel pipe going out of a small hole that is cut out of the bottom of the back side for an exhaust. Seems to squelch the sound fairly well. Good luck.
1/11/2018 1:31:08 PM • Honda Electrical... • Answered on Jan 11, 2018 • 829 views
0helpful
1answer

EG4000cl honda generator do you need to take of the front panel to remove the tank

yes the tank when all of the bolts removed will slide off the rubber mounts and out one end refitting is to remove the rubber , slide the tank back in and then put the rubbers back under the flange of the tank
1/6/2018 4:47:48 PM • Honda Electrical... • Answered on Jan 06, 2018 • 276 views
Not finding what you are looking for?
Honda Mmd 5000 Watt Electric Start Generator W/  Engine Ngk 6000HE Logo

35 questions posted

Ask a Question

Usually answered in minutes!

Top Honda Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...