No cold water
the cartrige might be it upside down or might be pluged turn water off to house remove handle unsrew cap and remove cartrige then flush out reassamble then turn water back on
No... on my single handle
Hi,
It seems as though you may have the wrong cartridge....
or it was damaged on installation...
or it is plugged with debris and needs to be flushed...
Click here for a sheet that will help you with all of these possible problems...
Comment back if you have any more questions...
heatman101
I have a moen posi-temp
you need to pull apart the handle and rotate the cartridge 180 and reassemble and that will put the hot on the left and the cold on the right before you put the screws all back in test it to make sure its correct then reassemble IF THIS HELPED YOU PLEASE VOTE FOR ME AND LEAVE GOOD FEEDBACK
I have been strugling with
look inside the valve with a flashlight and make sure a rubber peice of the cartridge did not plug the cold side this cartridge needs hot and cold water to function it has a built in balancer that prevents scalding also make sure its not shut down at a manabloc system in the mechanical room if this helped you please feedback vote thanks
I've been given an old
Moen and all shower valve manufacturers follow american federal guidelines. Hold the unit in your hand with the handle facing you - the left side is the hot water inlet and the right side is the cold water inlet.
No place to screw the
On your mixing valve, Your hot and cold water should hook to the valve at 9:00 and3:00 positions. You should have two ears at 12:00 and 6:00 positions which are used to screw the faceplate on. If you don't see these ears, the hole that the valve is in may not be big enough for you to see them. If it is tile, they may be covered with tile. If it is fiberglass, you would usually would have an oblong hole, longer at top and bottom, to see ears. If it is fiberglass, you may want to drill through where screws go, and through bolt your valve so it is tight. The hole in tile and/or concrete should be oblong so you can see screw holes.
My single moen posi temp
Remove the handle and see if it will turn off without the handle and if it will reposition the handle alignment and your good to go. If no the cartridge will need to be replaced.
Just changed the cartridge, cannot
The handle is not installed in the correct position. take it lose and line up the set screw in the same place it was on the old cartridge and tighten the set screw and you should be good to go.
The hot water has no flow . The cold has pressure
We had the same problem and tore the faucet apart. We found that the white plastic cartridge was not moving. After we pulled the white cartridge out we pulled the interior cartridge out of it (a metal cartridge) and found the inside of it was not moving. We put the end of the allen wrench into the hole of the valve area that allows the water flow and pushed it back out the end. Once we pushed it back together it was like it opened up and broke loose. This faucet was in a bathroom we use infrequently with a jacuzzi tub and we decided to use it again.
Single handle balances cold &
there could be dirt in the cartridge or the integral cold side shut off is not fully open. the integral shut off has a slot for a screw driver. the slot is to face the same direction as the pipe coming into it to be open and straight up and down to be off.