Intermatic T104 24h 208-277v Mechanical Time Switch - Answered Questions & Fixed issues

0helpful
1answer

Where I can buy the motor of a 24 hour dial time

I had an old Intermatic TN111 indoor timer with the red & green trippers laying around. I just drilled out the plastic plugs holding it together and popped out the timer motor. The timer motor is mechanically identical to the Malibu pool/lighting timer whose timer motor died.. As a bonus you get a spare load switch in case that ever fails.This works for 125VAC timers but not for 230VAC though if you have access to split phase you can run the motor off of 120 VAC and the load off of the 240 VAC
3/9/2023 9:54:13 PM • Intermatic T104... • Answered on Mar 09, 2023 • 77 views
0helpful
2answers

I replaced my pool clock ( Intermatic)twice. still

I have the same problem with the t104 clock. wired exactly to the diagram. this is the second one, the first one i thought it was a defective timer so i replaced it with another t104 and also wired it exactly to the diagram and still nothing. am i not doing something right???? line 1 to 1, line 2 to 3.....
8/19/2017 7:18:38 PM • Intermatic T104... • Answered on Aug 19, 2017 • 788 views
0helpful
1answer

How to wire intermatic t104 for 120v line and load

it won't work, it would if you had the guts from a 120 volt timer to put in, thats just not practical cuz you would have to get the right timer and at that time you might as well just replace the one your trying to rig up
7/6/2017 1:24:27 AM • Intermatic T104... • Answered on Jul 06, 2017 • 1,798 views
0helpful
1answer

T104 timer that has a 220volt clock

i would just replace the timer but you have that voltage for what its controlling you get the for that voltage
3/3/2017 1:05:12 PM • Intermatic T104... • Answered on Mar 03, 2017 • 809 views
0helpful
1answer

Installing lights where natural &hot wires go?

Is this about 120 volt T101 timer? http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101 Gene Water Heater Timers Save Money If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
7/19/2015 5:43:22 PM • Intermatic T104... • Answered on Jul 19, 2015 • 317 views
0helpful
1answer

How Do I Set an Intermatic Pool Timer

to set the time on it u rotate the dial use all if ur talking bout the off and on for the load use the trippers
6/12/2014 2:33:49 PM • Intermatic T104... • Answered on Jun 12, 2014 • 115 views
0helpful
1answer

Clock does not work but load does

really need more info. but assuming that ur turn it by hand to turn it on and off, it sounds as tho u have no power on the clock or the clock is bad. is it new? is it old and the clock quit, or new and the clock doesn't work? in this case may not have power to clock.
6/12/2014 2:27:37 PM • Intermatic T104... • Answered on Jun 12, 2014 • 176 views
0helpful
1answer

How to tell differance between 110 volts and 220 volts

u have to use a volt meter to find out for sure. if ur asking how to check it, u find the leads coming into it and take ur volt meter leads and if u have colored wires coming into it like black, red, white, green or bare which is ground. u check the volts by checking the volts 1st on ea of the colors. u should have 120 volts from ea color to ground, then u check volts between the colors. put ur leads to the red, black at the same time and u should have 240 volts. the colors may be black, white, and bare or ground. in this case treat the blk, and white as black and red.
6/12/2014 2:16:56 PM • Intermatic T104... • Answered on Jun 12, 2014 • 99 views
0helpful
1answer

Dimmer switch buzzing and lights won't stay lit

Check the rating of the dimmer switch. It is more than likely a 600-watt dimmer. Either way you should replace the dimmer switch with a 1000-watt rated dimmer switch.
1/2/2014 7:40:24 PM • Intermatic T104... • Answered on Jan 02, 2014 • 170 views
0helpful
1answer

How to install a new intermatic switch

10/10/2013 1:04:24 AM • Intermatic T104... • Answered on Oct 10, 2013 • 64 views
0helpful
1answer

Need manual for T104R

Copy following link for T104 product manual and wiringhttp://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.htmlGeneh If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
10/10/2013 1:00:42 AM • Intermatic T104... • Answered on Oct 10, 2013 • 106 views
0helpful
1answer

Timer Dial d note rotate Pumpm is operational Manually. Any Solution

1) Buy another clock motor:http://waterheatertimer.org/Intermatic-trippers-and-parts.html#T100http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timer.html2) Add a comment and include model number of timer. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
2/13/2013 7:50:25 AM • Intermatic T104... • Answered on Feb 13, 2013 • 47 views
0helpful
1answer

My company has model T104 208 volts but the lights come on than off than on than off light will not stay on .

1st of all if your not able to deal with electrical voltage's. if you feel you can not do this please call a electrician as 208 volts is very dangerous.A time switch only cuts power on and off at pre set times tho a set of mechanical contacts.with the on-off handle in the on position check power on the 'load side' of the timer switch, if power is there than its a problem with the light.
9/19/2012 12:53:00 AM • Intermatic T104... • Answered on Sep 19, 2012 • 56 views
0helpful
1answer

Pool timer clicking but doesnt keep time

If timer dial does not rotate and keep good time, then replace clock motor.Clock motor is getting weak, and maybe trippers are sticking on on-off lever.Add a bit of white grease to on-off lever, and turn power off then spray metal gears with bit of WD40. WD40 is highly flammable so power should be turned off.Copy following links for troubleshoot resources, and clock motor replacement.http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timer.htmlhttp://waterheatertimer.org/How-to-replace-Intermatic-clock-motor.html If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
8/20/2012 12:12:49 AM • Intermatic T104... • Answered on Aug 20, 2012 • 400 views
0helpful
1answer

Intermatic T104 timer manual switch stuck

To remove timer from enclosure, there is thumb spring located top inside box. Push up on spring, hold onto timer dial, tip outward and lift upward.Disconnect power before removing mechanism.Override lever should snap back and forth crisply, and turn pump ON-OFF.If override lever is not turning pump ON-OFF, then check that you have 240Volts across terminals 1 and 3. Check that timer dial is rotating and keeping good time.Then move override lever to ON position and check if you have 240Volt across terminals 2 and 4. These terminals are Hot when pump is supposed to be ON.Reset circuit breaker, may be tripped off on one leg, listen for crackling sound of loose breaker, use nose to smell for burning, tighten wires on breaker, move wires to another same-size circuit breaker.Copy following links for troubleshoot resources:http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timer.htmlhttp://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.htmlhttp://waterheatertimer.org/How-to-replace-circuit-breaker.htmlIf timer is not functioning, then buy clock motor and trippers.OR. You can buy the T104M mechanism-only, and snap into existing enclosure.OR. It may be cheaper: Buy the whole T104 and snap out of new enclosure and install mechanism into existing enclosure. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
7/20/2012 3:35:13 AM • Intermatic T104... • Answered on Jul 20, 2012 • 2,790 views
0helpful
1answer

Moved pointer intermatic T104

The time pointer is supposed to be stationary.On T104 timer the pointer is stationary pointed downward at 6:00 position. So you can move it so it is pointed straight down and add a bit of super glue where pointer meets stem.Copy following link for instructions how to set T104 timer:http://waterheatertimer.org/pdf/How-to-operate-and-set-T104-timer.pdf If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
7/5/2012 5:09:49 AM • Intermatic T104... • Answered on Jul 05, 2012 • 554 views
0helpful
2answers

I have a problem with wiring a model t 104

6/30/2012 10:31:22 AM • Intermatic T104... • Answered on Jun 30, 2012 • 496 views
0helpful
1answer

Ti04 clock rotates and new trippers but doesn't turn on

You probably have T104 timer.Clock rotates so power to timer motor is good. This means 240Volt breaker is good.Use override lever and see if Load (light, fan, motor) turns on and off. If override does not turn Load on-off, then bypass timer and see if load works. Move wires from terminal 2 to terminal 1, and terminals 4 to terminal 3.Did you order correct trippers?Copy following links for Intermatic troubleshooting and Intermatic parts list.http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timers.htmlhttp://waterheatertimer.org/Intermatic-trippers-and-parts.html#T100 If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
6/30/2012 6:32:56 AM • Intermatic T104... • Answered on Jun 30, 2012 • 229 views
Not finding what you are looking for?
Intermatic T104 24h 208-277v Mechanical Time Switch Logo

Popular Tags

131 questions posted

Ask a Question

Usually answered in minutes!

Top Intermatic Electrical Supplies Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Are you an Intermatic Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...