20 Most Recent Rheem 50 Gallon FVR NATGAS Water Heater 6YR 22V50F1 - Page 3 Questions & Answers

0helpful
1answer

Rheem 21V30-7P when pushing igniter button, heater

Probably clogged air intake, caused overheating, and TRD glass vial broke:Specific resources are available:http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.htmlRheem TRD:http://waterheatertimer.org/How-to-repair-Rheem-TRD.htmlForum:http://www.thetankatwaterheaterrescue.com/forums/forum3/Geneh If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
8/26/2013 1:02:29 AM • Rheem 50 Gallon... • Answered on Aug 26, 2013
0answers
0helpful
1answer

I have Rheem model 41V50 leaking from the top...The top is a lid with screw....can I buy and replace the top ?

No.Replace tank.Buy 40 gallon from local Lowes and install yourself.http://waterheatertimer.org/How-to-install-gas-water-heater.htmlUnder thin metal shell is a welded steel tank, surrounded by insulation and then covered with painted metal shell. The shell is what you look at.The inside steel tank is made to withstand high pressure expansion that comes with heating water.The steel tank has rusted out.Turn gas control valve to vacation, so pilot light stays on, and then only heat enough water as needed until you can replace tank.Prevent next tank from rusting by replacing anode rod, and ground water pipes.http://waterheatertimer.org/How-to-maintain-water-heater.html If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
4/9/2013 12:51:26 PM • Rheem 50 Gallon... • Answered on Apr 09, 2013
0helpful
1answer

Hotpoint water heater the electric igniter won't spark

Copy following link for troubleshooting igniter, and troubleshoot by type of gas control valve:http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#igniterAdd a comment and say what manufacturer appears on label.Open link above and scroll to top for information about FV lockout. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
3/16/2013 7:26:42 AM • Rheem 50 Gallon... • Answered on Mar 16, 2013
0helpful
1answer

How do I reset the safty system?

1) Copy following link:http://waterheatertimer.org/How-to-repair-Rheem-TRD.htmlhttp://waterheatertimer.org/pdf/Which-is-best-gas-water-heater.pdfhttp://waterheatertimer.org/How-to-install-gas-water-heater.html2) If this is Rheem-Richmond-Ruud, then you need new TRD glass vial.You may also need new gas control valve, EV sensor, and other parts.3) Might be cheaper to buy 40 gallon gas water heater at Lowes for $385, set 3-legged heater on bricks for ez access to arrestor screen, avoid dusty locations, provide more fresh air to unit, and perform required maintenance such as inspecting/cleaning air intake screen with compressed air. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
2/25/2013 9:28:16 AM • Rheem 50 Gallon... • Answered on Feb 25, 2013
0helpful
1answer

Water boiling out of the pressure relief valve

1) Copy following links for troubleshoot resources:http://waterheatertimer.org/How-to-replace-TP-valve.htmlhttp://waterheatertimer.org/pdf/How-to-replace-water-heater-gas-valve.pdf2) Problem indicates bad gas control valve thermostat.The dial located on gas control, is part of the thermostat on gas water heater. Copper probe protrudes into water heater, and this probe contains the ECO energy cut off and thermostat. Thermostats get out of calibration, or they fail. Replacement should be done by experienced person, otherwise it is relatively simple using pdf link above. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
2/18/2013 8:59:20 AM • Rheem 50 Gallon... • Answered on Feb 18, 2013
0helpful
1answer

Pilot light and burner go out

If it's a new installation, check for strong drafts around the unit. If not, the thermocouple most likely went out, They cost around 10 dollars and are easy to replace with a few common tools.
12/28/2012 5:08:50 AM • Rheem 50 Gallon... • Answered on Dec 28, 2012
0helpful
1answer

Went of vacation upon returning Rheem water heater not working unable to ignite burners

1) Copy following link to troubleshoot by type of gas control.http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#intellivent2) Clean air intake located under combustion parts, and check if TRD glass vial is broken due to overheating caused by reduce air intake and slowed exit of combustion by-product up the vent.http://waterheatertimer.org/How-to-repair-Rheem-TRD.html3) Post question on pro water heater forum:http://www.thetankatwaterheaterrescue.com/forums/forum3/ If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
12/3/2012 1:48:18 AM • Rheem 50 Gallon... • Answered on Dec 03, 2012
0helpful
1answer

Rheem water heater flashes seven times ,it is in lock out mode

You have Honeywell electronic gas control valve, and error code is 7 flashes.Probably you have power vent model.One manual from different company says: "Reset gas control using on-off button on front of control, replace flammable vapor sensor, replace gas control thermostat.But with Rheem you also need specific steps: Remove gas burner and look for broken glass vial, and then blow out arrestor screen air intake using compressed air, clean burner parts, check for unobstructed venting, you will need new glass vial from Rheem depending on year and model number of water heater that appears on label on side of unit, or they may not have a repair kit for that model, and you might need a new gas control valve depending on model and how extensive problem wasYou have Rheem water heater.http://waterheatertimer.org/How-to-repair-Rheem-FVIR.htmlhttp://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#intelliventhttp://waterheatertimer.org/How-to-replace-thermocouple.html If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
9/28/2012 11:24:18 PM • Rheem 50 Gallon... • Answered on Sep 28, 2012
0helpful
1answer

The indicator light stays on our PVS50 water heater.

You have the Robershaw wiper gas control valve.Here are error codes and troubleshoot table for that gas control.http://waterheatertimer.org/pdf/Robert-shaw-gas-control-error-codes-1610.pdfHere is general service manual for power vent water heaters.http://waterheatertimer.org/pdf/Power-vent-water-heater-service-manual.pdfHere is general parts list for that water heater, 2009:http://waterheatertimer.org/pdf/Rheem-power-vent-RS-parts.pdf If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
8/21/2012 7:26:40 AM • Rheem 50 Gallon... • Answered on Aug 21, 2012
0helpful
1answer

Power vent rheem mod pvw50 underneath is leaking

You have a water leak coming out of side of tank?Water heater must be replaced. It is rusted, and could rupture.Inspect and replace anode rod to prevent rusted tank, so water heater will last longer.http://waterheatertimer.org/Leaking-water-heater.htmlhttp://waterheatertimer.org/How-to-install-gas-water-heater.html If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
8/11/2012 12:38:48 AM • Rheem 50 Gallon... • Answered on Aug 11, 2012
Not finding what you are looking for?
Rheem 50 Gallon FVR NATGAS Water Heater 6YR 22V50F1 Logo

290 questions posted

Ask a Question

Usually answered in minutes!

Top Rheem Water Heaters Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Are you a Rheem Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Rheem Water Heaters

  • Rheem Water Heaters

Most Popular Question

burner not kicking in high flame

  • Water Heaters
Loading...