Kohler CH25 PA-CH730-0040 Command Gasoline Engine "wire kill switch" Questions

Ad

Question about Coleman Electrical Supplies

1 Answer

...wire in a kill switch the kill switch is not working, so im checking to see if its wired correct cause it has been replaced just eliminate and cut off the wire to the existing kill switch the put any ...

Ad

Question about Watts Electrical Supplies

1 Answer

kill wire ( if I remember it is the brown wire) that is disconnected on one end or the other Or your in coach switch is bad. Check the switch this way Remove the switch from the dash/ mounting surface

Ad

...to A kill switch wire works by stopping power to the switch by connecting to ground..usually the engine..but any unpainted surface will do..just make sure it is a clean contact and tight..good

kill switch. Just unplug oil alert wire from harness and add a homemade connector with second lead and connect another wire to ground/frame of generator engine. When you short these two wires together

Question about Briggs & Stratton Electrical Supplies

1 Answer

...Kill Switch but they do fail, and are no necessarily replaced. The wire you speak of is most likely the wire that shorts the ignition to ground causing the engine to stop. Any momentary push button ...

Question about Briggs & Stratton Electrical Supplies

1 Answer

...kill wire to ground. On some generators, there will be another method of shutting down the engine. Usually on/off switch will be more visable on the control panel. Most likely the switch on fan cover ...

Question about Electrical Supplies

1 Answer

...kill the engine.... run 2 wires to the remote switch. One wire will connect to the low oil level sensor wire (if oil level sensor has 2 wires only one will work../ trial and error) ) and the other to ...

Question about Electrical Supplies

1 Answer

...kill wire from coil diconnected generator puts out 120 volts If you have an ohm letter or continuity tester, put the probes across switch and depress kill while reading meter for a change in ...

...home onan generator 4000 watt has no spark out of coil to plugs? check and see if it gas a kill switch some were on it follw a black wire out of coil see were it goes maybe to a kill switch look for ...

Question about Coleman Electrical Supplies

1 Answer

kill wire that attaches to the ignition module (coil), the other end of the kill wire connects to the center terminal of the on/off switch. A white wire runs from the switch to the oil shutdown module

Not finding what you are looking for?
Kohler CH25 PA-CH730-0040 Command Gasoline Engine Logo

296 questions posted

Ask a Question

Usually answered in minutes!

Top Kohler Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Are you a Kohler Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...