...low oil pressure shutdown until filter is filled with oil. Is there a sump oil level sensor that has stuck when oil was drained and now causing a no oil shutdown ? The battery indicator may not be ...

Ad

Question about Powermate Electrical Supplies

1 Answer

low oil sensor The generator shutdown and it won't restart. Oil was low, refilled it, and it still won't start. How long should we wait to try and start it again? I would let it cool ...

Ad

Question about Kohler Electrical Supplies

1 Answer

low lube oil sensor problem first. Could be low oil pressure or a failed sensor. The sensor is timed and if pressure doesn't come up, then unit is shutdown. Check fuel filter and also air leaks in the

Question about Onan Electrical Supplies

1 Answer

...low oil pressure shutdown switch. First check the oil level. If oil level is low, fill oil to proper level. If oil level is fine, I would install an auxiliary oil pressure gauge . If oil pressure is ...

Question about Taylor Electrical Supplies

1 Answer

...a few things that control this: The battery, the low oil shutdown switch, and the run switch, and associated wiring. If I were to ventture a guess, I would put money on the low oil shutdown

Question about Multiquip Electrical Supplies

1 Answer

...and top it up its most liky low and low oil shutdown is kicking in if it still wont run try checking main jet , then try cleaning out carb and replacing plug then check for tight in / ex valve s ...

Question about Kohler Electrical Supplies

1 Answer

...runs like nothing wrong. New fuel line, filter, pump, fuel tank cleaned, oil level good and clean. Check for intermittent oil pressure switch. Monitor the possibility of low oil pressure

Question about Coleman Electrical Supplies

1 Answer

Coleman Powermate 5000W generator - Won't stay on My generator will start however it will only stay on a few minutes then shuts itself off. Can you help me? add some oil they have a low oil shutdown

...getting hot enough to set off low oil /shutdown 1. check and wash rediator 2. check thermostat valve working properly 3. check valve tiiming and fuel consumtion 4. otherwise engine needs complete ...

Question about Coleman Electrical Supplies

1 Answer

No start, no spark. Filled with oil. Still no spark Removed wire from LOW OIL SHUTDOWN. STILL NO SPARK What do I do next check the operation of the on/off switch

Not finding what you are looking for?
Kohler 17 kW Emergency Power System - 17RES-L Logo

17 questions posted

Ask a Question

Usually answered in minutes!

Top Kohler Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66847 Answers

Are you a Kohler Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...