...brushes are worn out, no excitation field is supplied and no output is generated. Replace carbon brush if found worn-out. Use an analog multitester to check the continuity of the carbon brush and the ...
Question about Northstar Electrical Supplies
...brushes are worn out, no excitation field is supplied and no output is generated. Replace carbon brush if found worn-out. Use an analog multitester to check the continuity of the carbon brush and the ...
...replace the brushes. The "furthest in" brush (black wire) is always broken and it appears that the casing for the brush melts. What could be the problem? Sometimes it will work for a month. Other ...
Question about Coleman Electrical Supplies
...brushes. This board has a capacitor about 1 inch long and 3/4 inch dia. If the capacitor looks swollen or burned replace board or carefully remove cap and replace with similar. You can use a larger ...
...generator won't generate replaced brushes, circut breakers, windings show continuedy any ideas ? Check rotor again and measure to see if you have DC voltage on the brushes while running. If no ...
Question about Pramac Electrical Supplies
generator is putting out 150 volts, why Loaded circuit or open circuit? If loaded, brushes need cleaning before buying parts. Check manual for procedure on your model. The brushes are usually culprit.
Question about Electrical Supplies
...rotor. Re-initialize Bad brushes. Replace Glaze contact rings. Clean Shorted or open rotor. Replace Bad AVR. Replace Bad field supplying the AVR voltage control voltage. Replace alternator
...brushes have worn and are not contacting rings. Examine commutator rings for smooth surface. Remove diode board and check for leaking capacitor. If it is split open, burned or swollen replace as ...
...be very smooth with no pits or out of round or brush will wear very fast due to arching. Ring is replaceable however lots of work. Good ...
brushes it will have a capasitor that is prob out of spec. Pull off the cover at the end of the generator and locate a 2 lead capacitor, it should read 130UF 200V and replace it, they often go bad and
696 questions posted
Usually answered in minutes!
64 Questions
57 Questions
47 Questions