Whirlpool LGB6300 Gas Dryer "faulty solenoid" Questions

Ad

GAS DRYER, THE IGNITER GETS RED HOT BUT THE GAS DOES NOT COME OUT AND FIRE UP This is most likely faulty gas valve coils. These coils are located right above the gas valves. These solenoids, when ...

Ad

...goes out, runs 2 min, reignites, burns for 30 sec and goes back out This is most likely caused by faulty gas valve coils. The electrical coils are right above the gas valves and when energized, ...

Ad

...for 1-2 minutes then shuts off and comes on again a few minutes later This is most likely caused by faulty gas valve coils. The electrical coils are right above the gas valves and when energized, ...

Question about LG Dryers

1 Answer

...an orange color if it is working. If the ignitor seems to be working properly, then I would suspect faulty gas valve coils. These are solenoids located directly above the gas valves, that when ...

...will not come on when start the dryer If the ignitor is operating properly, then I would suspect faulty gas valve coils. These coils are situated right above the gas valves and when these

dryer don't heat. ignator lights up but flame not come I would suspect faulty gas valve coils. These electrical coils are right above the gas valves and when energized, these solenoids open the gas ...

solenoid. Yep. If the ignitor is working properly and the dryer won't light, then it is most likely faulty gas valve coils. These electrical coils are right above the gas valves. These solenoids, when

...plug lights but does not fire gas everything else works fine just wont heat up This is most likely faulty gas valve coils. These electrical coils are located just above the gas valves and when ...

Question about LG Dryers

1 Answer

...solenoid is faulty DLE5955 dryer makes clicking noise when tumbling, only tumbles for 4-5 spins at a time then stops for about 2 minutes. Clicking solenoid draws lots of power as lighting in house ...

...When these solenoids are energized, they open the gas valves and permit the burner to light. If faulty, they don't open the valves to permit gas flow. Due to the difficulty in testing these ...

Not finding what you are looking for?
Whirlpool LGB6300 Gas Dryer Logo

211 questions posted

Ask a Question

Usually answered in minutes!

Top Whirlpool Dryers Experts

Virgil Watts

Level 2 Expert

267 Answers

Brad Brown

Level 3 Expert

19187 Answers

Paul Bade

Level 3 Expert

1818 Answers

Are you a Whirlpool Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...