Question about Konica Minolta bizhub Office Equipment & Supplies
Konica Minolta dirty copies I am getting black ink dirty copies with my konica minolta c550. After taking out the black imaging unit I noticed there is black powder acummulating on one side of the ...
Question about Konica Minolta bizhub Office Equipment & Supplies
...etc.. the developer from your imaging unit become to fall causing developer on edge of paper(dirty
Question about Konica Minolta bizhub Office Equipment & Supplies
...imaging unit EEPROM acces error. Clean the connection between the imaging unit and the machine if dirty.Reinstall imaging unit or change imaging unit. Try reset: Turn OFF the copier. Press and keep ...
Question about Konica Minolta bizhub Office Equipment & Supplies
I HAVE Konica Minolta Konica Minolta C550 .WHEN I USED COPY OR PRINT EXITING PEAPER IS DIRTY OR HAVE BAR BLACK. PLEASE GUIDE ME "Dirty" could be one of 3 things... Transfer belt, Imaging unit and ...
...Magenta Imaging Unit EEPROM access erro. you need to: 1. check if EErpom of Magenta Unit is not dirty. if it is, clean it. Else, replace the Unit
Question about Konica Minolta bizhub Office Equipment & Supplies
Dirty mark appering at across top edge of paper on both sides on bizhub 351 imaging unit was replaced recently but problem didn't develop until now. if marks are repeating themselves (same ...
...test pattern failure 1 Wipe clean the surface of the transfer belt with a soft cloth, if it is dirty. 2 Change the image transfer belt unit if the transfer belt is damaged. 3 Change the PH unit. ...
...recently make sure it is sitting in the correct position, if not the contacts on the chip might be dirty, if it still doesn't work you might need a new image ...
Question about Konica Minolta bizhub Office Equipment & Supplies
...test pattern failure 1 Wipe clean the surface of the transfer belt with a soft cloth, if it is dirty. 2 Change the image transfer belt unit if the transfer belt is damaged. 3 Change the PH unit. ...
8650 machine error 21 1 Wipe clean the surface of the transfer belt with a soft cloth, if it is dirty. 2 Change the image transfer belt unit if the transfer belt is damaged. 3 Change the PH unit. 4 ...