1 Answer

...if the engine speed is low. You need to use either a DMM with a HZ function to set the engine speed so that you get 61.5 Hz at no load, or use a tachometer to set the no load speed to 3750 rpm. ...

Ad

...possible causes for fault? Low frequency is caused by the engine not running at it's correct speed. There is a governor mechanism that controls the engine speed, so I'd check it for proper

Ad

engine starts and i try to open the choke it starts to back fire bace line carb settings hope this helps The adjustment on the bottom of the float bowl is the main jet. Adjust this one for high speed.

Question about Coleman Electrical Supplies

2 Answers

...Engine speed is low, does your meter read frequency? Set for 60 Hz @ speed. I doubt there is a voltage regulator adjustment. This may help Probably just an engine speed issue. Try increasing the RPM ...

Question about Coleman Electrical Supplies

1 Answer

...engine speed is not constant. Anyone have a diagram or picture of the springs for the speed control? If the unit was stored for a long period of time (6-12 mo.) with gas in it, you may have a gummed ...

Question about Yamaha Electrical Supplies

3 Answers

...engine speed with no load to produce 61.5Hrz but the voltage remains low at 103VAC. When I switch on some load (an AC Unit) the frequency drops to 60.5Hrz but the voltage stays at 103 VAC. Welcome. I ...

Question about Generac Electrical Supplies

1 Answer

my generac gp7000 has low voltage Low voltage? how low? Assuming engine speed is correct, first check the capacitor in the end of the alternator housing. Common problem

Question about Briggs & Stratton Electrical Supplies

1 Answer

generator voltage too low generator voltage output too low check engine speed by the sound...if normal then check AVR card...replace it... if not normal rase it...

Question about Briggs & Stratton Electrical Supplies

1 Answer

...Engine model number and I will stll you how to adjust the governor speed. This is GENERIC but the Governor arm has a spring that connects to a speed plate. The speed plate has a stand off screw and ...

Question about Desa International Electrical Supplies

1 Answer

...engine, runs fine GENERATER has extemly low output on 115 and 240 V check to make sure your spark plug is clean and that your rpm is set right. if the rpm on the engine is not right it will not put ...

Not finding what you are looking for?
Kohler 20resa 20kw Home Emergency Backup Generator Logo

14 questions posted

Ask a Question

Usually answered in minutes!

Top Kohler Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Are you a Kohler Electrical Supply Expert? Answer questions, earn points and help others