Omega 5hp 1740RPM 184TC Frame 230 Volts Leeson Electric Motor # 131602 "motor leeson" Questions

Ad

Question about Leeson Tools & Hardware - Others

1 Answer

what happens to a 240v electric motor if you hook up the same phase 110v to each of the 2 lines It will not run. With only one wire hooked to both leads there is no potential and no place for the ...

Ad

Question about Leeson Tools & Hardware - Others

1 Answer

i need a diagram to wire it to a saw should be a wiring diagram on the wiring cover.

Ad

Question about Leeson Tools & Hardware - Others

1 Answer

I have Delco Model 2J2424r1, frame 56R, Series A84, phase 3 electric motor. What is the wiring diagram to run it under 230VAC? If it has 9 leads and is a 240/480 volt motor the 1and 7 go to line 1. ...

Question about Leeson Tools & Hardware - Others

2 Answers

...input voltage check to see if its the proper phase check tension on belts, gear, or connection from motor OK I happen to be working on one at this minute. Here is the switch diagram with proper L and ...

Question about Leeson Tools & Hardware - Others

1 Answer

I have a 3/4 HP motor installed on my porch chairlift that has stopped working. The motor only hums when you push the up or down button. After removing the motor it spins freely and will run but has ...

Question about Leeson Tools & Hardware - Others

1 Answer

my account been change what do ido It depends on what type of account, but if this is your credit card, call the 800 number on the card and report an erroneos charge, they will ask you a series of ...

Question about Omega Tools & Hardware - Others

1 Answer

how to conect 3 phase motor 9 yellow wires from p1 how to conect 3 phase motor 9 yellow wires from t1 to t9 Connect t4,t5,t6 together. Connect t1,t7 together for line 1. Connect t2,t8 together for ...

Question about Leeson Tools & Hardware - Others

1 Answer

junction box detail drawing is missed for motors 15hp 50hz 380v and double boles please send drowing . Here is a diagram the contactor needs a 120Volt supply & switch too.

Question about Leeson Tools & Hardware - Others

1 Answer

3450rpm motor how to check the over load swich MOTOR SHOULD HAVE A RESET BUTTON. IF U CAN FIND IT, HOLD IT IN-IF MOTOR RUNS RESET MAY HAVE TO BE REPLACED.MAKE SURE MOTOR DOES NOT OVERHEAT UNDER ...

Not finding what you are looking for?
Omega 5hp 1740RPM 184TC Frame  230 Volts Leeson Electric Motor # 131602 Logo

2 questions posted

Ask a Question

Usually answered in minutes!

Top Omega Tools & Hardware - Others Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

ADMIN Eric
ADMIN Eric

Level 3 Expert

39389 Answers

Larry Ng
Larry Ng

Level 3 Expert

14598 Answers

Are you an Omega Tool and Hardware - Other Expert? Answer questions, earn points and help others

Answer questions