Okay...these are general to Yamaha igniter systems...
so bike is in neutral...shows neutral, kill switch on...
Test each plug cap with a new spark plug...if one or more getting no spark....
Unhook the pickup coil harness and test the resistance (the P U coils located in left front crankcase cover with stator. If resistance tests out fine, ensure the connector is clean and connect.
Now test that both ignition coil packs primary and secondary resistances are within spec.
Verify the ignition coil packs are getting battery voltage to the primary terminal (often a red/white wire).
Ensure the igniter (the ignition black box) also called TCI is getting battery voltage on its supply.
Ensure all connectors clean to TCI.
The only other issue may be the interlocks are trying to shut down ignition....typically a black/white wire from the igniter goes to sidestand relay, tip over switch....both shut down ignition by grounding the control side of the TCI...could be they are partially grounding allowing minimal ignition.