05 yukon denali xl try to stall and winding sound on driver inside floor when taking off then tries to stall or maybe the trans hold like in neutruel

5 Related Answers

Anonymous

  • 1 Answer
  • Posted on Oct 20, 2008

SOURCE: location of fuse box/panel for 2004 yukon denali xl

There are 2 fuse panels in the Denali.
One is a panel on the drivers side, its on the dash but facing the door.

The ohter is under the dash and above the pedals, this one is much tougher to access.

Your Owner's Manual should tell you where the fuses are that you need to access.

Ad

Anonymous

  • 3 Answers
  • Posted on Dec 30, 2008

SOURCE: 2004 yukon xl denali self-leveling rear air shocks

There's a lever that connects the driver-side rear shock to the Automatic Level Control module (the air compressor and the ride-height sensor). Disconnect the lever from the shock and rotate it up and hold it. The compressor should kick in when you hold in place after a few seconds. If it doesn't kick in, make sure your fuses and relays are good. Otherwise, you may have a failed ALC module/burned out air compressor (from the shocks being shot). After you replace the shocks (and after you recouped from the heart attack you had when you shelled out $500+ for each shock), replace the ALC module/compressor (it's all one unit), and test it - it should kick on when you rotate the lever up again.

Figure about $350 for the ALC module from your dealer, and make sure the part numbers match! Your truck came with an upgraded ALC module from the 2001-2004 module, which were prone to water damage.

Good luck!

Anonymous

  • 94 Answers
  • Posted on Mar 16, 2009

SOURCE: 2005 gmc yukon xl denali service ride control

it has to do with your air ride suspension best bet is take it to the dealer there is probably a problem with a level sensor. hope this helps you

Anonymous

  • 57 Answers
  • Posted on Jun 14, 2009

SOURCE: lost reverse on GMC Yukon Denali vortex drives

WOW sorry to hear that.

this is a common problem with the 4l60e transmission, what has happend is the gear has sheared off the back of the sun shell, you should have lost reverse and if you will watch your tachometer the next time you drive you will notice you allso lost forth gear.

you will nedd to have the transmission removed and disassembled for the new sun shell, make sure you get the hardened sun shell, this is not a rebuild but simply a repair. you can get a stock sun shell for about $65.00 or a heavy duty one for about $100.00, make sure you find a good tranny guy to provide the labor, oh the transmission paper rubber kit "reseal kit" shouldnt be more than about $80.00

good luck

[email protected]

Jonah Oneal

  • 14092 Answers
  • Posted on Sep 28, 2009

SOURCE: What the normal transmission temp Yukon Denali XL 2008

TRANSMISSION FLUID NORMAL TEMPERATURE IS 200 DEGREES.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I have an 05 Yukon xl Denali. Trans action message keeps coming up and transmission doesn’t feel right. Any ideas what this message means? Thank you

Check the fluid. Then have the codes read. It may have a bad shift control solenoid. The CEC may hold the key to your repair.
0helpful
1answer

Bose amp

Next time it does it take your fist and hit the top of the console armrest, toward the rear of the armrest, if it stops suspect the Rear Seat Audio module, I'm assuming you have one because I've replaced 3 in the last few months for this exact problem,it sounds like an alt. whine up and down with the engine speed, yes the amp is bolted to the floor under the console, you can pop that RSA module out and let it hang until it makes the noise and then lightly hold it and tap on it to see if the noise goes away. The RSA needs to be programmed to the truck at a dealer.
Hope this helps
EZ
1helpful
1answer

2005 gmc yukon xl blower is not shutting off. It continues to run after the vehicle is shut off. Any suggestions?

Sounds like a faulty blower motor resistor also check wire connector for melting.Location is next to floor on in heat duct towards the left of pass side feet area.
0helpful
2answers

Driver side power window and both front heated seats won t work on 2004 Yukon denali

checkl fusers and cables to that
the problem is 100% with power
Not finding what you are looking for?

109 views

Ask a Question

Usually answered in minutes!

Top GMC Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

john h

Level 3 Expert

29494 Answers

Are you a GMC Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...