Check to make sure that you have enought freon to engage the compressor, then you will need a flow chart to take you through the rest of the steps necessary to diagnos this problem. The Electrical system manual for Buick is the only one that will have the proper information for you to walk through the steps to dead head it. There is a HVAC programer that is behind the floor heater duck work. It has a numbering system that goes from (2) rows of pins that go 1-16 for terminals.On terminal 5-7 with ignition in run position, you need bat. votage. Terminal 10 & 11 you need 4-5 volts. Neither 10 or 11 should be unplugged just yet since 10 feeds 11 pin. If there isn't any voltage at these pins, check for corrosion on the pins theirself, or for the pin that it may have slipped back out of the connector. Good luck.
Fig. Fig. 1 Blower resistor assembly is underneath the fuse block
REMOVAL & INSTALLATION
1,271 views
Usually answered in minutes!
Put control module into self diagnostic mode and came up with codes 38 & 152, no letters. What do these codes mean specifically?
Put control module into self diagnostic mode and came up with codes 38 & 152, no letters. What do these codes mean specifically?
×