1 Answer

What will cause a sunroof not to close properly on a 2007 Milan


A lot of thing's , has sensors , switches , a control module , relay's etc....
The roof opening panel is an electronically operated panel that can be opened or closed by pressing a switch located on the overhead console. It also has one-touch open, one-touch close, one-touch vent open and one-touch vent close features.

Roof Opening Panel The roof opening panel assembly uses an integrated motor and module to operate the roof opening panel. The roof opening panel motor and module are installed new as an assembly. The roof opening panel is an electronically operated glass panel that can be opened, closed or tilted by the roof opening panel switch. Actuating the switch in either a forward or rearward motion supplies a ground to the roof opening panel motor/module. The roof opening panel has one-touch open and one-touch close features that are activated when the switch is momentarily pressed to the double detent OPEN or CLOSE position. These functions are controlled by the roof opening panel motor/module.
The roof opening panel motor must be initialized whenever the roof opening panel motor has been removed from the roof opening panel system, the roof opening panel assembly has been removed from the vehicle, a new roof opening panel motor has been installed or a new roof opening panel assembly has been installed.

Plus the mechnical parts of it .

Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Roof opening panel frame
  • Roof opening panel drain hoses
  • Roof opening panel lifter assemblies
  • Roof opening panel trough
  • Roof opening panel air deflector assembly
  • Roof opening panel seal
  • Roof opening panel shield
  • Battery junction box (BJB) fuse 33 (20A)
  • Smart junction box (SJB) fuse 12 (7.5A)
  • Circuitry
  • Accessory delay relay
  • Roof opening panel motor and module assembly
  • Roof opening panel switch

Mar 20, 2017 | 2007 Mercury Milan

1 Answer

Sun roof won't close 2004 Ford Explorer


The roof opening panel is an electronically operated panel that can be opened or closed by the roof opening panel switch. Actuating the switch in either a forward or rearward motion supplies a ground to the roof opening panel motor. The vent and soft-stop functions are controlled by the roof opening panel motor. These positions are obtained when an internal motor cam opens the roof position switch, removing the ground from the switch. The roof opening panel has an express open feature activated when the switch is pressed momentarily. The roof opening panel is closed by continuous activation of the switch until the sunroof stops movement. This function is controlled by the roof opening panel motor.

Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Opening shield
  • Roof panel frame
  • Opening shield guide feet
  • Central junction box (CJB) fuses:
    • 2 (20A)
    • 29 (5A)
  • Battery junction box (BJB) fuse 1 (60A)
  • Accessory delay relay
  • Roof opening panel control switch
  • Circuitry
  • Roof opening panel motor

  • The roof opening panel does not open or close
  • Central junction box (CJB) fuse:
    • 2 (20A).
    • 29 (5A).
  • Battery junction box (BJB) fuse 1 (60A).
  • Circuitry.
  • Roof opening panel control switch.
  • Roof opening panel motor.
  • Go To Pinpoint Test E .

Do the power windows and power locks work ?

E6 CHECK VOLTAGE TO THE ROOF OPENING PANEL MOTOR - CIRCUITS 400 (LB/BK) AND 1173 (BN/OG)
  • Key in OFF position.
  • Disconnect: Roof Opening Panel Motor C920.
  • Key in ON position.
  • NOTE: Activate accessory delay relay for this check.
  • Measure the voltage between roof opening panel motor C920-4, circuit 400 (LB/BK), and ground; and between roof opening panel motor C920-7, circuit 1173 (BN/OG), and ground.
  • Are the voltages greater than 10 volts?
Yes
GO to E7 .

No
REPAIR circuit 400 (LB/BK) or circuit 1173 (BN/OG). TEST the system for normal operation. If you can't do electrical testing , there is a manual way to close it .
Roof Opening Panel Manual Operation
  1. Remove the overhead console. For additional information, refer to Overhead Console in this section.
  1. Insert a hex-head screwdriver in the center of the manual drive slot to depress the release pin. Rotate the screwdriver clockwise until the roof opening panel is closed.

Jan 13, 2017 | 2004 Ford Explorer

1 Answer

Sunroof will not close. Was working fine earlier today


The roof opening panel assembly uses an integrated motor and module to operate the roof opening panel. The roof opening panel motor and module are installed new as an assembly. The roof opening panel is an electronically operated glass panel that can be opened or closed by the roof opening panel switch. Actuating the switch in either a forward or rearward motion supplies a ground to the roof opening panel motor/module. The soft-stop function is controlled by the roof opening panel motor/module. The roof opening panel has 3 modes of operation, manual mode, express open and tilt. The express open feature is activated when the switch is pressed momentarily. The tilt feature is activated when the tilt switch is depressed. These functions are controlled by the roof opening panel motor/module.
Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Roof opening panel frame
  • Roof opening panel drain hoses
  • Roof opening panel lifter assemblies
  • Roof opening panel water trough
  • Roof opening panel rear trough guides
  • Roof opening panel air deflector assembly
  • Roof opening panel seal
  • Roof opening panel shield
  • Smart junction box (SJB) circuit breaker 47 (30A)
  • Circuitry
  • Accessory delay relay
  • Roof opening panel switch
  • The roof opening panel does not open or close - one direction only
  • Circuitry
  • Roof opening panel switch
  • Roof opening panel motor assembly
  • Go To Pinpoint Test E .
PINPOINT TEST E: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSE Test Step Result / Action to Take E1 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES FOR OBSTRUCTIONS OR DAMAGE
  • Check the roof opening panel lifter assemblies for obstructions and damage.
  • Are the roof opening panel lifter assemblies OK?
Yes
GO to E2 .

No
REMOVE all obstructions and REPAIR any damage. If lifter assemblies cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel Frame in this section. TEST the system for normal operation. E2 CHECK THE ROOF OPENING PANEL WATER TROUGH AND REAR TROUGH GUIDES
  • Check the water roof opening panel water trough and rear trough guides for any loose obstructions.
  • Are the roof opening panel water trough and rear trough guides installed securely and free from obstructions?
Yes
GO to E3 .

No
REMOVE all obstructions from the roof opening panel water trough and install securely. SECURE the rear trough guides or INSTALL new roof opening panel rear trough guides if damaged. REFER to Roof Opening Panel Rear Trough Guide in this section. TEST the system for normal operation. E3 VERIFY THE ROOF OPENING PANEL ADJUSTMENT
  • Verify the roof opening panel is adjusted correctly.
  • Is the roof opening panel adjusted correctly?
Yes
GO to E4 .

No
ADJUST the roof opening panel. REFER to Roof Opening Panel Alignment - Horizontal Adjustment and Roof Opening Panel Alignment - Height Adjustment in this section. TEST the system for normal operation. E4 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR INITIALIZATION
    NOTE: The roof opening panel motor initialization procedure must be done when repairs are carried out on any part of the roof opening panel assembly, including whenever the roof opening panel motor/module has been removed from the roof opening panel assembly, a new roof opening panel motor/module has been installed or when a new roof opening panel assembly has been installed. Refer to Roof Opening Panel Motor Initialization in this section.
  • Carry out the Roof Opening Panel Motor Initialization procedure. Refer to Roof Opening Panel Motor Initialization in this section.
  • If the concern still present?
Yes
GO to E5 .

No
The system is operating correctly. The roof opening panel motor/module was uninitialized. E5 CHECK THE POWER WINDOWS
  • Key in ON position.
  • Verify the power windows operate.
  • Do the power windows operate?
Yes
GO to E6 .

No
REFER to Section 501-11 to diagnose the accessory delay relay circuit. E6 CHECK THE ROOF OPENING PANEL SWITCH
  • Carry out the roof opening panel switch component test. Refer to Wiring Diagrams Cell 149 for schematic and connector information.
  • Did the roof opening panel switch pass the component test?
Yes
GO to E7 .

No
INSTALL a new roof opening panel switch. TEST the system for normal operation. E7 CHECK CIRCUIT CBP47 (GN/BU) FOR VOLTAGE
  • Key in OFF position.
  • Disconnect: Roof Opening Panel Motor/Module C922.
  • Key in ON position.
  • Measure the voltage between roof opening panel motor/module C922-4, circuit CBP47 (GN/BU), harness side and ground.
    s7j~tr~en~file=a0083978.gif~gen~ref.gif
  • Is the voltage greater than 9 volts but less than 16 volts?
Yes
GO to E8 .

No
VERIFY the smart junction box (SJB) circuit breaker 47 (30A) is OK. If OK, REPAIR the circuit. TEST the system for normal operation. E8 CHECK CIRCUIT GD143 (BK/VT) FOR AN OPEN
  • Key in OFF position.
  • Measure the resistance between roof opening panel motor/module C922-3, circuit GD143 (BK/VT), harness side and ground.
    s7j~tr~en~file=a0084276.gif~gen~ref.gif
  • Is the resistance less than 5 ohms?
Yes
GO to E9 .

No
REPAIR the circuit. TEST the system for normal operation. E9 CHECK CIRCUITS CPR37 (YE/GY), CPR39 (VT/WH) AND CPR40 (YE/OG) FOR AN OPEN
  • Disconnect: Roof Opening Panel Switch C930.
  • Measure the resistance between the roof opening panel motor/module C922-1, circuit CPR40 (YE/OG), harness side and roof opening panel switch C930-8, circuit CPR40 (YE/OG), harness side. Measure the resistance between roof opening panel motor/module C922-2, circuit CPR39 (VT/WH), harness side and roof opening panel switch C930-11, circuit CPR39 (VT/WH), harness side. Measure the resistance between roof opening panel motor/module C922-5, circuit CPR37 (YE/GY), harness side and roof opening panel switch C930-14, circuit CPR37 (YE/GY), harness side.
    s7j~tr~en~file=n0054600.gif~gen~ref.gif
  • Are the resistances less than 5 ohms?
Yes
GO to E10 .

No
REPAIR the circuit. TEST the system for normal operation. E10 CHECK FOR CORRECT ROOF OPENING PANEL MOTOR/MODULE OPERATION
  • Disconnect the roof opening panel motor/module connectors.
  • Check for:
    • corrosion.
    • pushed-out pins.
  • Connect all roof opening panel motor/module connectors and make sure they seat correctly.
  • Operate the system and verify that the concern is still present.
  • Is the concern still present?
Yes
CHECK the jumper harness between the vehicle harness and the roof opening panel for open or shorted circuits. If the jumper harness is not OK, INSTALL a new jumper harness between the vehicle harness to the roof opening panel motor/module. Otherwise, INSTALL a new roof opening panel module/motor. REFER to Roof Opening Panel Motor in this section. TEST the system for normal operation.

No
The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.

May 08, 2016 | 2008 Ford Expedition El

1 Answer

Pop trunk open


plese i have code kaon 607

Feb 24, 2014 | Chevrolet Equinox Cars & Trucks

1 Answer

Dash board says door is open in my 2002 honda accord but it's not actually open


have you checked the door switch to see if it makes: open/close contact??;maybe try pushing the switch all the way in by hand, with door open, to see if light goes off/on and if it does,then switch is not working properly and not being pushed all the way in when door closes.

Dec 21, 2013 | 2002 Honda Accord

1 Answer

Can I open the rear glass when the gate is open. I have a large item that needs to get into the car via the gate, but I only need the window open after that. If not ... how do I get it done (forcefully)...


You should be able to open the window and the gate. If the window won't open while the gate is open, try opening the window first, then opening the gate.

Good Luck!
~Brandon

May 29, 2011 | 2005 Mitsubishi Endeavor

1 Answer

Trunk wont open. latch does not work from inside


Make sure the drivers door is open and push the button on the drivers door to open trunk. Keep the drivers door open while you open trunk. If you close the drivers door before opening it, it won't open. Well this is what happens to our car. Don't know if it's a fault or the design but this does work for us.

Jul 03, 2009 | 1997 Saab 900

4 Answers

Sun roof will nt close cant find the rite fuse


check fuse F1.401, 30 amp in central junction box (in truck). Check your owner manual for fuse information.
Headliner must be removed to access motor.



Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Roof opening panel frame
  • Roof opening panel drain hoses
  • Roof opening panel lifter assemblies
  • Roof opening panel water trough
  • Roof opening panel air deflector assembly
  • Roof opening panel seal
  • Roof opening panel shield
  • Battery junction box (BJB) fuse
  • Circuitry
  • Accessory delay relay
  • Roof opening panel switch


  • The roof opening panel does not open or close
  • Roof opening panel adjustment.
  • Battery junction box (BJB) fuse.
  • Circuitry.
  • Roof opening panel switch.
  • Roof opening panel motor assembly.
  • Roof opening panel lifter assemblies.


  • The roof opening panel does not open or close — one direction only
  • Circuitry.
  • Roof opening panel switch.
  • Roof opening panel motor assembly.



Apr 10, 2009 | 2003 Lincoln Navigator

1 Answer

Thermostat


It should open when it gets up to the opening temperature. Better way to test it is to put the water in the pot, hot from the tap, and put it on the stove. Put a thermometer in there too so you can monitor the temp. Drop in the thermostat, then heat the water on the stove. When it opens, note the temperature that the opening occurs at - then you can see if it's opening at the correct temperature. If you put it in boiling water, it'll open - but you won't know if it opened at the right temp.

Aug 17, 2008 | 2000 Volkswagen Golf

Not finding what you are looking for?
1999 Volvo C70 Logo

Related Topics:

45 people viewed this question

Ask a Question

Usually answered in minutes!

Top Volvo Experts

Marvin
Marvin

Level 3 Expert

84619 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22484 Answers

Jonah Oneal

Level 3 Expert

14092 Answers

Are you a Volvo Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...