Alan Bowles Posted on Sep 20, 2012

2007 COLORADO WONT SWITCH TO DEFROST OR FLOOR MODES

My 2007 Colorado will not switch between the different heater control modes. no matter where it is set, it only blows out the regular dashboard vents. Any ideas as to what is wrong with it?

5 Related Answers

Anonymous

  • 1 Answer
  • Posted on Jul 22, 2008

SOURCE: There is no air flow

You need part GM Part number 89018675 or ACDelco 15-73596. The Mode Selector Actuator. What happens is the part is a CHEAP part POORLY designed and when it goes to turn the flaps inside the HVAC unit its the plastic gear slips instead of turning the flap!!!

Just to forward you you might want a deal to install this art for you unless your good at fixing your own vehicle, because you need SMALL sockets and a lot of patience to get this part in!!!

The part is ALMOST directly above the steering shaft for your steering wheel, so theres a lot you got to remove before you will even see them!!!

I only recommend you to have a dealer put this part in for you, unless you have your own service manual!!

Because there is 5 of these darn things and if you pick the wrong one you will have to do it all over again!!!

3 on the Drivers side and 2 on the Passengers side!!

But replacing this part SHOULD solve all your problems!! AS it did for me and i was having the same issues as you have described!!


Ad

mikehumble

  • 124 Answers
  • Posted on Dec 13, 2008

SOURCE: heater control 98 chevy s10 blazer

These trucks have a problem where moisture builds up in the heater box then freezes. When this freezes and you change your heater settings it breaks the shaft for the blend door. If this is what happened you should be able to look under the dash above and to the right of the gas pedal and you will see two vaccuum accuators one of them you should be able to wiggle around the linkage if it is broke. To fix this you need to remove the entire dash to get the heater box out which involves discharging the AC and draining the coolant because the heater core and evaporator come out. Please rate.

Anonymous

  • 150 Answers
  • Posted on Feb 17, 2009

SOURCE: A/C heater vents will only blow out the defrost ducts.

Some times you can "reset" the computer for that by disconnecting the battery for 15 or 20 seconds then re-connecting it. If that doesn't work then the mode door motor assy might have stripped gears or broken gears. (they are plastic) If you are familiar with where the mode door motor assy is you can turn the knob to change the mode (i.e. defrost, panel, floor) and see if the motor is turning. If motor is turning and mode does not change then the plastic pieces have broke or stripped. Usually when there is a problem with the climate control system it will default to the defrost simply as a safety thing. So you will have defrost so you can see where you are going. Hope this helps you all out, good luck.

Anonymous

  • 20 Answers
  • Posted on Feb 23, 2009

SOURCE: Heat wont blow through heater or defroster vents

common problem, check under dash by the gas pedal if control arms are muving went selecting from ac to heat cuz this it is the control for the vents to go from ac to heat and to defrost.

Anonymous

  • 1959 Answers
  • Posted on Sep 05, 2009

SOURCE: A/C only blows through defrost vents

It sounds like the blend door actuator which diverts air from defrost to vent to the floor.
The bad news is it's a bear to get at. It's located behind the glove box.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

My heater wont switch from feet to defrost but see it switch on the control mode on the floor also when on defrost outside opens. Up what is bad

The Blend Doors, or Blend Door Actuators on your MYSTERY vehicle are not operating how they should. They move and direct the air where you specify.

'year make model' in all questions please!
0helpful
1answer

Why wont my 2001 ford windstar blow out of vents ? only on defrost?

Air Flow Control
Air flow control is accomplished in the following manner:
  • Primary control is through the function selector knob , mounted on the heater function selector switch, which is part of the heater control .
  • The function selector knob has the following positions: OFF, PANEL, PANEL/FLOOR, FLOOR, FLOOR/DEFROST and DEFROST.
  • The heater function selector switch combines a vacuum selector valve with an internal electrical switch.
  • The vacuum selector valve directs source vacuum to various vacuum control motors (18A318) . Refer to the System Airflow Schematic and Vacuum Control Charts.
  • An internal single-pole electrical switch is also controlled by the selector. The switch controls the electrical supply to the heater blower motor switch (18578) .
  • The position of the function selector knob determines the manner in which the system will operate.
  • Each position of the function selector knob is detented for positive engagement.
  • You probably have a vacuum leak , Pull heater control panel an check for vacuum . A broke vacuum hose or The vacuum selector valve is bad ! Or check for a vacuum hose in the engine compartment being off somewhere !
0helpful
1answer

Hearter temp control was blowing too hot, now only blows cold

Clicking sound you hear is the worn brushes in your blower motor. At this point the blower moter may or may not start with the switch. THe blower motor is faulty so I would change that first, then check for vacuum leaks or faulty selector cable for the heat blend door. It could have came off door side or heater control side.
1helpful
1answer

2007 DODGE durango heater control

HAVC Vent Door/Motor problem
Need a service manual or repair shop
1helpful
1answer

Heater and AC and blower all work fine but it all blows out of defroster vents thats about it , when AC is on it comes out defroster vents,no matter your selection. Heater is the same way.

The HVAC mode selections on these are controlled by an electric stepper motor that receives commands from the BCM (body control module). The BCM decides where the air door should be by looking at where the dash control input is.
Each mode selected has a different resistance level. From low resistance to high resistance: Panel, Bi-Level, Floor, Mix and Defrost, with Defrost as the highest resistance (~100K ohms). A high resistance or open circuit would probably default the system to defrost no matter what position the mode control was set to.
If the control is dirty or there is a connection issue, this could cause this problem. Does playing with the control make any difference?
The BCM can store fault codes with HVAC releated information. The system can be reset and recalibrated with a battery disconnect, this will also erase any fault codes.
I would start by looking at the dash mode control.

Good luck, i hope this helps.
0helpful
1answer

2000 Buick LeSabre air only comes out on the floor

They have two types of air conditiong controls. AUTOMATIC & MANUAL . Your mode switch maybe bad if manual. If automatic the head is probably bad and they are sold as exchanged units only. If manual check all circuits to see if 12 volts has continuity
1helpful
1answer

2007 F-150 Supercrew Lariat Cabin Air Filter

According to the shop manual you do not have one.
Air Distribution and Filtering adobe.gif Printable View (79 KB) NOTE: The air distribution system of this vehicle cannot be equipped with a cabin air filter.
There are 2 sources of air available to the air distribution system:
  • Outside air
  • Recirculated air
Recirculated air is automatically used when the electronic manual temperature control mode selector is set in the MAX A/C or OFF modes and can be selected in any mode other than MAX A/C, OFF or DEFROST by selecting the RECIRC button. Recirculated air is available in all modes except DEFROST. If the vehicle is equipped with an electronic automatic temperature control (EATC) system, recirculated air is used in OFF and is available in all modes except DEFROST. RECIRC mode is a timed function in FLOOR and FLOOR/DEFROST.
Air distribution within the vehicle is determined by the electronic manual temperature control (EMTC) function selector switch position, or is controlled by the EATC system in the AUTOMATIC mode. The air distribution mode on EATC vehicles may be overridden by the driver if desired. Air distribution doors are used to direct airflow within the heater core and evaporator core housing and the plenum chamber. An electronic mode door actuator is used to position these air distribution doors. One air inlet mode door is used to switch between FRESH or RECIRC air inlet. An electric actuator is used to position the air inlet mode door.
Air enters the passenger compartment from the:
  • instrument panel A/C registers.
  • heater outlet floor ducts.
  • windshield defroster duct.
  • side window demisters.
  • center flow-through console (if equipped).
Passenger compartment air is exhausted from the vehicle through open windows or body air vents.
4helpful
1answer

Switch on dashboard does not change air direction to flow & vents

Defrost is the default mode so if the system fais, you alays have defrost. The mode doors are controlled by vacuum motors. I would suspect a vacuum leak in the engine compartment on the hose going from the engine through the firewall and into the heater controls. Some systems have a vacuum storage canister that can also leak. The canister stores vacuum when vacuum drops going up a hill.
Or, you have a bad heater control head that is not passing vacuum to the vacuum motors on the mode doors.

Here's a diagram of the system for reference.

826b4f9.gif
0helpful
1answer

Heater

U need to check the vacuum to the mode control switch at the back of the AC/heater control, if there is vacuum replace the vacuum switch, if no vacuum check for broken small vacuum line at the engine.
0helpful
2answers

Heater

Pull the AC control in the dash and verify that there is vacuum going to it, all the different air diversion doors are operated by seperate vacuum motors controlled by the ac control head in the dash, as you switch it it sends vacuum to the correct location to work that door for the desired air outlet, dash, floor etc..
Not finding what you are looking for?

1,538 views

Ask a Question

Usually answered in minutes!

Top Chevrolet Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

john h

Level 3 Expert

29494 Answers

Are you a Chevrolet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...