1987 Toyota Camry Logo
Frank Klepach Posted on Jul 21, 2012

The blower motor on 1987 camry works intermit. is this a bad resistor?

Could the resistor be causing problem or is it the motor when it works the motor works fine

1 Answer

Merle Horton

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 3 Answers
  • Posted on Aug 31, 2012
Merle Horton
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Aug 31, 2012
Answers
3
Questions
1
Helped
487
Points
7

Find the blower resister board that is attached to the air manifold just behind the glove box. It will have a plug attached to it. remove this board from the plastic or cardboard air plunum and check for any coils that are broken. The air traveling through the plunum serves to cool the coils. When the coils break, you loose a motor speed. If the motor is intermittant at any or all speeds, then motor is going bad. JC Witney!

5 Related Answers

Anonymous

  • 2 Answers
  • Posted on Jun 02, 2008

SOURCE: 1989 toyota camry blower just stopped

find your fuse layout or owners manual and check the fuse and replace it even if it looks ok,thencheck to see if the switch itself is bad,if so replace it by removing the screws,(4-6) and dash cover checking the connection and switch,replace which ever one is bad and turn on the car,turn one the switch if nothing happens the switch is bad replace and enjoy!

Ad

Anonymous

  • 373 Answers
  • Posted on Jul 21, 2008

SOURCE: Where is blower motor resistor

HI....
The BLOWER motor resistor on a Toyota Camry 01.
Is located Behind center right side of dash.
ON blower housing.
If you vehicle is equipaded with protection cover.
Just you need to remove the cover. and will see the blower resistor.

I hope this information work for you.

Thank you for use fixya.

Anonymous

  • 154 Answers
  • Posted on Jul 28, 2008

SOURCE: Blower motor has only low speed

You may need to get the correct resistor, as they are designed to only allow so much amperage to go through them. If it is getting very hot it is runnig to many amps through it. It will eventually blow and you will need to replace it anyway.

Anonymous

  • 29 Answers
  • Posted on Jan 19, 2009

SOURCE: broken power steering belt

no your p/s belt just takes is spun by the crank shaft. if its not making noise when you turn the key, then you should check the fuses under the dash and under the hood for ign one of those might be bad.

Anonymous

  • 855 Answers
  • Posted on Sep 25, 2009

SOURCE: Heater on 1990 Toyota Camry mysteriously quits

If you mean the blower stops, make sure you have access to the blower. Turn on heater when blower stops check to make sure it still has power which I think it will. This will tell you that the blower motor is going bad and shutting down when it is warmed up. To repair just replace the blower motor.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Heater fan only works on high

this sounds like you need the resistor that allows the blower motor to operate on the different speeds. if you follow the wires from the blower motor back they lead to the resistor that needs replacing. this is a common problem and are designed to only operate on high if the resistors go bad.
0helpful
2answers

95 toyota camry replace blower motor resistor

The resister puts current to the motor when you change
speeds on switch so if you motor only work in one or two
speeds you no the resister is bad if you put current direct to
motor make sure. It runs if ok change resister thank you and please reply
0helpful
2answers

A/C BLOWER MOTOR rus slow intermitently at all settings

Could be the blower motor, or the resistor.
I would check the voltage at the blower motor first.
The ground circuit goes thru the resistor and controls the speed.
0helpful
1answer

I have a 1999 camry. The fan only works on high. On high it works well so it's not a motor issue. I've checked the fuses and they are good. Any thoughts?

It sounds like the resistor block for your heater/AC fan has gone bad. Here's a link to a few I found on line for the 1999 camry to give you an idea of the cost. When the resistor block goes bad the motor defaults to its highest setting.

http://www.drivewire.com/vehicle/1999-toyota-camry/heater-blower-motor-resistor/

A local autoparts store like autozone should also carry this part. They will also probably be able to give you some advice about how to install it.

I hope this helps you out.
4helpful
1answer

Blower motor on 2000 toyota camry works only on hi settig

Hi!!
The blower motor speeds are ultimately controlled by the Blower Motor Resistor, when the Resistor becomes defective, current goes right thru it and the Blower Motor only operates at max. speed. Replacing the Resistor is a simple task. Locate electrical connector to blower motor, trace back wiring no more than 8" to next plug, The device where the plug is connected to is the Blower Motor Resistor, disconnect plug and remove the two screws, remove and replace Resistor.
Good Luck!! A HELPFUL - 4 THUMBS - rating for this solution would be greatly appreciated. Thank you for using FixYa.
2helpful
1answer

Fan speed only works on high

the blower motor resistor has gone bad, replace the blower motor resistor and it will operate properly
1helpful
1answer

1999 camry blower fan only works on high setting

this problem is caused by the blower speed control resistor, it is located near the blower motor.
1helpful
1answer

Pug 205 1987 Blower not Blowing

IT COULD BE BLOWER MOTOR NOT GROUNDED.YOUR BLOWER MOTOR FUSE AND RELAY COULD BE BAD.MAKE SURE POWER IS GOING TO BLOWER.MOTOR.CHECK TO SEE IF POWER IS GOING TO SWITCH IF SO SWITCH COULD BE BAD.HOT WIRE BLOWER MOTOR USING JUMPER WIRE AND POWER FROM THE BATTERY.IF BLOWER MOTOR WORKS.YOU HAVE FUSE RELAY AND SWITCH PROBLEM.MOST THE TIME WHEN RESISTOR BAD.YOUR BLOWER MOTOR ONLY WORK ONE SPEED SOME TIME.
1helpful
1answer

Intermitant Blower Motor

2 possible causes. 1 when blower is not working try banging on motor if it goes on thats the problem if not possible blower fan speed resistor.
3helpful
1answer

Where is blower motor resistor located on a 2001 Toyota Camry?

HI....
The BLOWER motor resistor on a Toyota Camry 01.
Is located Behind center right side of dash.
ON blower housing.
If you vehicle is equipaded with protection cover.
Just you need to remove the cover. and will see the blower resistor.

I hope this information work for you.

Thank you for use fixya.
Not finding what you are looking for?

219 views

Ask a Question

Usually answered in minutes!

Top Toyota Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

ROBERT GARCIA
ROBERT GARCIA

Level 3 Expert

926 Answers

Are you a Toyota Expert? Answer questions, earn points and help others

Answer questions