Put 12 volt power to terminals on fan itself, if the fan works its the switch thats bad. or a fuse or relay ! if need be try and get another switch from same vehicle at junk yard. because the dealers are out to rob you. replace switch if motor and fuses are good. check the wires at motor to see if they are getting voltage. if not the switch is bad. sometimes if blower motor resistor is bad, fan will not blow on any speed. check this first. its beside the fan motor. if you need more info, just type in on computer. location of blower motor 2001 intrigue. good-day !
HEATER BLOWER MOTOR
Its
faulty blower motor resistor. The low and medium speed on blower motor is
controlled by resistor and its actual speed is high. So because resistor is not
working, blower motors actual speed which is high is working.
It
can be faulty blower motor or faulty blower motor resistor. Get the blower
motor inspected. If it's faulty it has to be replaced.
=======
For
blower motor testing and replacing, check the link below: ----
http://repairhelpcenter.blogspot.in/2012/02/blower-motor-replacing-for-all-vehicles.html
------------
These will help.
Thanks.
446 views